NT2000 injection pump test bench (screen display) operation introduction

First, start the program Turn on the computer power, start WINDOWS, test bench program will be executed automatically, the screen displays the main screen. On the screen there are five digital table display, including the tachometer, the number of times the oil, advance angle, positive and negative pressure gauge, thermometer. There are several buttons on the screen to perform various functions. Second, set the speed with the tachometer and the amount of oil below the table there are ten circular buttons, click with one of the mouse, the button turns red, the table is selected the file preset speed, the button below the number of pre- Set speed value. In the parked state, the speed value is also displayed in the tachometer (Preset value when light blue is displayed; Actual speed value when red light is displayed.) Click the button below the tachometer to increase or decrease the speed value 1; hold down the button, the speed value will change rapidly. In parking mode, click the tachometer, pop-up keypad window on the screen, use these keys to directly enter a preset value, OK and click OK key, if wrong use the key to eliminate. Repeat the above steps to set all preset files. Third, start the main point machine First select a preset file, and then click the forward or reverse button, the main point machine starts, at the same time forward or reverse button into a bright color, that is running; press the stop button main point machine stop. In operation, the tachometer shows the current actual speed. Click any of the preset button, the main engine will run at the speed set by the preset file. Fourth, the automatic speed control system can achieve automatic speed control, so that the actual speed as much as possible with the set speed, when the main motor from stop to run, or switch from the current speed to another preset speed, the program makes the automatic speed control becomes invalid ; Until the main motor speed reaches a stable (delay a few seconds), so that automatic speed control becomes effective, the button becomes highlighted color. You can click the button at any time to make the automatic speed regulation effective. Click or button, the automatic speed control becomes invalid. In this case, you can use the or button to adjust the speed manually. The method is the same as speed presetting. Fifth, the amount of oil count (1) set the amount of oil count in the stop state, the amount of oil count table may be displayed before the count value, click the stop button, then display the preset quantity of oil. Click the preset button, the preset amount of oil displayed in the table, and pop-up keypad window on the screen, you can directly enter the amount of oil, the method with the speed preset. You can also use the number of panels on the number of plus / minus the number of keys to 50 times the number of modified fuel. (2) Count / stop Press the count button to start counting. The program detects the count signal, the relay action, and then start counting from 0, when the set amount of oil reaches the time, disconnect the relay, the count is over. Press the stop button to stop counting at any time. The fuel gauge shows the last count value. Sixth, the use of temperature control In the thermometer below the three buttons, the button to switch the actual temperature and set the temperature display. Click the button to make it highlighted, and the thermometer shows the set temperature. Use the and buttons to modify the setpoint temperature, each time you click, the temperature increases or decreases by 1 degree. Click the button to make it appear as normal. Thermometer shows the current actual temperature. Click the temperature control button, make it turn red, temperature control effective at this time. Temperature program by controlling the heating and air-cooled, the oil temperature maintained at the set temperature value. Click the temperature control button again to cancel the temperature control, and the button will resume normal display. Seven other functions Pump button control pump motor start and stop. Each time you click the button, the color of the button changes once. When the display is red, the oil pump is started, and when it is light, the oil pump is stopped. Query button to achieve various models of fuel injection pump information. Print button to print the verification report. Exit button: Exit the program and return to the WINDOWS interface.